ZBL-P8000 Wireless Foundation Pile Dynamic Detector - Beijing ZBL Sci And Tech

Return

ZBL-P8000 Wireless Foundation Pile Dynamic Detector

Field of use:By using the reflected wave method, the apparatus is used to assess the integrality of concrete pile and identify the extent and location of the pile defect. It can be used for testing perfusion pile and hammer pile. It can also be used for testing the exposed top surface of constructions such as pillars.
Configurations:Wireless sensorPADHammer
New wavelet analysis and processing technique, effective extraction of the pile bottom reflection signal; Real-time automatic processing of the testing waveform (smoothing, integral, filtering wave, index, linear magnification, etc.); Sign


Parameter

Specification

Amplifier frequency band

 1~10k (Hz)

A/D resolution

24 bit A/D

Sampling time intervals

6.4μs~1638.4μs

Maximum length of sampling

≥2048

Amplitude nonlinear degree

≤10%

Dynamic range

≥144 (dB)

Error of time indication

≤1%

Gain error

≤1dB%

Transducer sensitivity

≥100 mV/g (Acceleration Mode)

Amplifier frequency range

0.59000 Hz

Battery Operating Time

>5 hours

Power

lithium battery

Total weight

Approx 0.34kg

Fixed point magnification

1, 2, 4, 8, 16, 32,64

Controller

PDA with sunlight viewable touchscreen display

Data Storage

Yes

Software


Side bar navigation